There are 1216 products.

Active filters

Danfoss Inverter FC302 132kW 380-500VAC/3PH IP21

Frequency converterFC-302P132T5E21H2XGX7XXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P132) 132 KW / 200 HP

Three phase380 - 500 VACIP21 / Type 1

RFI Filter

No brake chopper

Graphical Loc. Cont. Panel

Not coated PCBFuse

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: D2

Other options according to Model code

Danfoss Inverter FC302 132kW 380-500VAC/3PH IP54

Frequency converterFC-302N110T5E54H2XGCXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(N110) 110 KW / 150 HP

Three phase380 - 500 VAC(E54) IP54 / Type 12

RFI Filter

No brake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: D1H

Other options according to Model code

Danfoss Inverter FC302 132kW 380-500VAC/3PH IP54

Frequency converterFC-302N132T5E54H2XGCXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(N132) 132 KW / 200 HP

Three phase380 - 500 VAC(E54) IP54 / Type 12

RFI Filter

No brake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: D1H

Other options according to Model code

Danfoss Inverter FC302 132kW 380VAC/3PH IP20 BRAKE Frame:D3H

Frequency converterFC-302N132T5E20H2BGCXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(N132) 132 KW / 200 HP

Three phase380 - 500 VAC

(E20) IP20 / Chassis

RFI FilterBrake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: D3H

Other options according to Model code

Danfoss Inverter FC302 132KW 380VAC/3PH IP21

Frequency converterFC-302N132T5E21N2XGCXXXSXXXXA0BXCXXXXDXVLT®

AutomationDrive FC-302(N132) 132 KW / 200 HP

Three phase380 - 500 VACIP21 / Type 1LHD - AAF006 filter + A2

RFI

No brake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.PROFIBUS DP MCA 101, No B OptionNo C1 option, No D option

Frame: D1n

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC IP55

Frequency converterFC-302P15KT5E55H2XGXXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VACIP55 / Type 12

RFI Filter

No brake chopper

Graphical Loc. Cont. Panel

Not coated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B1

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC/3PH IP20

Frequency converterFC-302P15KT5E20H2XGXXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VAC

(E20) IP20 / Chassis

RFI Filter

No brake chopper

Graphical Loc. Cont. Panel

Not coated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B3

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC/3PH IP20

Frequency converterFC-302P15KT5E20H2BGXXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VAC

(E20) IP20 / Chassis

RFI FilterBrake chopper

Graphical Loc. Cont. Panel

Not coated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B3

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC/3PH IP20

Frequency converterFC-302P15KT5E20H2XGCXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VAC

(E20) IP20 / Chassis

RFI Filter

No brake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B3

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC/3PH IP21

Frequency converterFC-302P15KT5E21H2XGXXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VACIP21 / Type 1

RFI Filter

No brake chopper

Graphical Loc. Cont. Panel

Not coated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B1

Other options according to Model code

Danfoss Inverter FC302 15kW 380-500VAC/3PH IP55

Frequency converterFC-302P15KT5E55H2XGCXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VACIP55 / Type 12

RFI Filter

No brake chopper

Graphical Loc. Cont. PanelCoated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B1

Other options according to Model code

Danfoss Inverter FC302 15kW 380VAC/3PH IP20

Frequency converterFC-302P15KT5E20H1XGXXXXSXXXXAXBXCXXXXDXVLT®

AutomationDrive FC-302(P15K) 15 KW / 20 HP

Three phase380 - 500 VAC

(E20) IP20 / Chassis(H1)

RFI Class A1/B (C1)

No brake chopper

Graphical Loc. Cont. Panel

Not coated PCB

No Mains Option

Latest release std. SW.

No A Option, No B OptionNo C1 option, No D option

Frame: B3

Other options according to Model code