Danfoss Softstarter MCD201-022-T4-CV1 22 KW
Product Number: 175G5179
MCD201022T4CV1
175G5179
MCD201022T4CV1
VLT® Compact Starter MCD 201
22 kW 48A:4-6: 354
Three phase, 200-440 VAC
Control voltage: 24 VAC/VDC
(A) A-Frame
Model code:MCD201022T4CV1
VLT® Compact Starter MCD 200 from Danfoss includes twofamilies of soft starters in the power range 7.5–110 kW.The series offers easy DIN rail mounting for sizes up to 30 kW,2-wire or 3-wire start/stop control and excellent startingduty (4 x Ie for 6 seconds).Heavy starting rating at 4x Ie for 20 seconds.Compatible with grounded delta power systems
4 other products in the same category:
Viewed products
Brake Resistor 40 0hm/1.8kw
175U1848
This product has been discontinued.
Type: ZRF 55/600 072 40R
for VLT types: 2880/5016 / FC300 P11K (380-480 / 500V)
Nominal power: 2.0kW
Resistance value: 40Ohm
Braking power:
10% ED / cycle 120s 14.0kW
Degree of protection: IP20
Housing dimensions HxWxD: 120 x 186 x 735mm
Weight: 5.8kg
Danfoss Softstarter MCD201-045-T4-CV3 45KW
MCD201045T4CV3
175G5171
MCD201045T4CV3
VLT® Compact Starter MCD 201
45 kW 85A:4-6: 594
Three phase, 200-440 VAC
Control voltage: 110/240 VAC or 440 VAC
(B) B-Frame
Model code:MCD201045T4CV3
VLT® Compact Starter MCD 200 from Danfoss includes twofamilies of soft starters in the power range 7.5–110 kW.The series offers easy DIN rail mounting for sizes up to 30 kW,2-wire or 3-wire start/stop control and excellent startingduty (4 x Ie for 6 seconds).Heavy starting rating at 4x Ie for 20 seconds.Compatible with grounded delta power systems
Danfoss Softstarter MCD2 018-T4-CV3 18.5kW
MCD201018T4CV3
175G5167
MCD201018T4CV3
VLT® Compact Starter MCD 201
18 kW 42A:4-6: 354
Three phase, 200-440 VAC
Control voltage: 110/240 VAC or 440 VAC
(A) A-Frame
Model code:MCD201018T4CV3
VLT® Compact Starter MCD 200 from Danfoss includes twofamilies of soft starters in the power range 7.5–110 kW.The series offers easy DIN rail mounting for sizes up to 30 kW,2-wire or 3-wire start/stop control and excellent startingduty (4 x Ie for 6 seconds).Heavy starting rating at 4x Ie for 20 seconds.Compatible with grounded delta power systems
Danfoss Softstarter MCD 500 MCD5-0331B-T5-G3X-00-CV2
MCD50331BT5G3X00CV2134N9349This product has been discontinued.MCD50331BT5G3X00CV2VLT® Soft Starter MCD 500200-525 VAC, 331A, IP00,Control Voltage: 110 VAC and 220 VACModel code:MCD50331BT5G3X00CV2VLT® Soft Starter MCD 500 is a total motor starting solution.Current transformers measure motor current and provide feedback for controlled motor ramp profiles. AAC, the Adaptive Acceleration Control automatically employs the best starting and stopping profile for the application
Danfoss Softstarter MCD2 015-T4-CV3 15KW
MCD201015T4CV3
175G5166
MCD201015T4CV3
VLT® Compact Starter MCD 201
15 kW 34A:4-6: 354
Three phase, 200-440 VAC
Control voltage: 110/240 VAC or 440 VAC
(A) A-Frame
Model code:MCD201015T4CV3
VLT® Compact Starter MCD 200 from Danfoss includes twofamilies of soft starters in the power range 7.5–110 kW.The series offers easy DIN rail mounting for sizes up to 30 kW,2-wire or 3-wire start/stop control and excellent startingduty (4 x Ie for 6 seconds).Heavy starting rating at 4x Ie for 20 seconds.Compatible with grounded delta power systems